Specifications

3-21
Setting the reference value for dot misalignment correction [PG DROP ADJUST.]
5 Press the [] or [] key to correct the dot position of pattern 1.
Select the correct dot position on [PATTERN 1] using the JOG key [] or [].
Select the dot position where the dots of outward trip and those of homeward trip form a straight line on the test
pattern.
6 Press the [ENTER] key.
7 Subsequently repeat Steps 5 and 6 seven times to make PG DROP ADJUSTMENT on
Pattern 2 to Pattern 8.
Select the correct dot position on each of the patterns.
Enter the adjusted values on Patterns 1 to 8 and then terminate PG DROP ADJUSTMENT.
8 Press the [END] key several times.
The printer returns to LOCAL mode.
Input COMP value.
-40.0 - +40.0
PG DROP ADJUST.
PATTERN1 = 0.0
Input range:
Patterns 1 to 8
-40.0 to 40.0
Output direction
The dots at the fourth position counted
from the zero position in the positive
direction form a straight line.
In this case, the adjusted value is 4.0.
Input COMP value.
-40.0 - +40.0
PG DROP ADJUST.
PATTERN2 = 0.0
Input range:
Patterns 1 to 8
-40.0 to 40.0
L. >
width : ∗∗∗∗ mm