Specifications

6 Operation for Functions
6-34
Setting the temperatures and standby time of heaters
Set the temperatures and standby time of heaters by the following procedure:
STEPS:
1 Make sure that the printer is in LOCAL mode.
If it is in REMOTE mode, press the [REMOTE] key once.
2 Select [SET UP] using the [FUNCTION] key and press the [ENTER] key.
Select type 1 to 4 and press the [ENTER] key.
3 Select [HEATER] by pressing the [] key twice and press the [ENTER] key.
[SET TEMP.] is displayed.
4 Press the [ENTER] key to go to the lower level of hierarchy and input the setting val-
ues of heater temperatures using appropriate ones of the [], [], [] and [] keys.
Use the [] or [] key to change the setting values of temperatures, the [] or [] key to move the cursor,
and the [ENTER] key to register the setting values in memory.
5 Press the [] key, select [SET TIME], and set [SET TIME].
Use the [] or [] key to change the seting value of the time, the [] or [] key to move the cursor, and the
[ENTER] key to register the setting values in memory. (0 ~ 90 min (In steps of 10 minutes) )
6 Press the [END] key several times.
The printer returns to LOCAL mode.
L. >
width : ∗∗∗∗ mm
FUNCTION
SET UP <ENT>
SET UP
SELECT : TYPE 1
[1]
HEATER <ent>
[1]
MEDIA COMP. <ent>
Twice
INPUT RANGE
OFF, 20 - 60 °C
PRE PRT POST
OFF OFF 50°C
Input range:
PRE [OFF, 20 - 60] ° C
PRT [OFF, 20 - 60] ° C
POST [OFF, 20 - 70] ° C
[1] HEATER
SET TIME <ent>
StandbySwitchoverTIM
NONE, 0 - 90 min
STANDBY : OFF TIME
10 min : NONE
L. >
width : ∗∗∗∗ mm