Specifications
6 Operation for Functions
6-20
Outline of the machine setup functions
DRY & EXHAUST FAN
DRYNESS FAN
Set operation of the dryness fan.
STOP TIME
Set the time from the completion of printing to the stop of the fan.
Available setting values: [ CONT. , 0 ~ 240 min ] ( Default: 120 min [In steps of 10 minutes] )
[CONT.] means that the fan is always kept operating.
RENEW
Change fan operation. ( The fan motor operates according to the setting.)
Available setting values: [ON , OFF]
The setting is not stored in memory.
The dryness fan operates during printing and behaves according to the setting of the stop timer after
completion of printing.
OUTSIDE EXHAUST FAN
Set the operation of the outside exhaust fan when the fan is equipped.
As a default, the outside exhaust fan operates in conjunction with the dryness fan setting. If switched to
independent operation, different setting from the dryness fan is available.
STOP TIME
Set the time from the completion of printing to the stop of the fan.
Available setting values: [ CONT. , 0 ~ 240 min ] ( Default: 120 min [In steps of 10 minutes] )
[CONT.] means that the fan is always kept operating.
RENEW
Change fan operation. ( The fan motor operates according to the setting.)
Available setting values: [ON , OFF]
The setting is not stored in memory.
The outside exhaust fan operates during printing and behaves according to the setting of the stop timer
after completion of printing.
SETUP INTERLOCK
Switch to the operation that is interlocked with the dryness fan setting.