Specifications
4-19
Before executing the [PUMP TUBE WASH]
Before executing the [PUMP TUBE WASH]
Before executing the [PUMP TUBE WASH] or [Wiper cleaning] function, the tubes must be filled with the
cleaning solution.
Filling the tubes with the cleaning solution [MaintWashLiquid]
Supply and discharge the cleaning liquid for the wiper and pump tubes.
STEPS:
1 Make sure that the printer is in LOCAL mode, and then select [MAINTENANCE] using
the [FUNCTION] key and press the [ENTER] key.
If it is in REMOTE mode, press the [REMOTE] key once.
2 Select [HD.MAINTENANCE] by pressing the [] key twice and press the [ENTER] key.
3 Select [MaintWashLiquid] by pressing the [] key once and press the [ENTER] key.
4 At this point, either of [FILLING UP] and [DISCHARGE] can be selected by pressing
the [] or [] key.
If there is a problem with the waste ink tank, the display will show either of the
following messages.
Follow the displayed instructions to restore the normal conditions.
No waste ink tank,
or a tank is FULL.
<ENT>keyHIT is after
theTANK set or exchg
Replace a
waste ink tank.
<ENT>keyHIT is after
the TANK exchange.
L. ∗ >
width : ∗∗∗∗ mm
FUNCTION
MAINTENANCE <ENT>
MAINTENANCE
ST.MAINTENANCE <ent>
MAINTENANCE
HD.MAINTENANCE <ent>
Twice
HD.MAINTENANCE
MaintWashLiquid <ent>
HD.MAINTENANCE
FILL UP INK <ent>
Twice
MaintWashLiquid
DISCHARGE <ent>
MaintWashLiquid
FILLING UP <ent>
To step 5 To step 11