Specifications
2 Before Use
2-18
NCU functions
NCU functions are displayed only when the machine is equipped with the
optional nozzle check unit (OPT-J0218).
Function name Sub function Setting value Function
NOZZLE CHECK (Refer to P.6-24 in this manual.) ON, OFF Set whether or not to perform nozzle
missing detection.
NG ACTION (*1)
[DURING THE
DRAW]
(Refer to P.6-24 in
this manual.)
CONTINUE Set the operation of the printer to be
performed during printing in case a
certain level of nozzle missing is
detected and thus NG judgment is
made. (*2)
CLEAN-
ING&CONT
CLEANING
TYPE
NORMAL, SOFT, HARD
CLEAN-
ING&STOP
CLEANING
TYPE
NORMAL, SOFT, HARD
RETRY COUNT 0 to 3
STOP
NG ACTION (*1)
[AFTERtheDRA-
Wend]
(Refer to P.6-25 in
this manual.)
CONTINUE Set the operation of the printer to be
performed after completion of print-
ing of one file in case a certain level
of nozzle missing is detected and
thus NG judgment is made. (*2)
CLEAN-
ING&CONT
CLEANING
TYPE
NORMAL, SOFT, HARD
CLEAN-
ING&STOP
CLEANING
TYPE
NORMAL, SOFT, HARD
RETRY COUNT 0 to 3
STOP
NG JUDGEMENT
(*1)
(Refer to P.6-25 in
this manual.)
CLOGG NZL/color 1 to 180 Set the number of missing nozzles
per row for judging the nozzle check
NG . (*2)
CLOGG NZL/ALL 1 to 180 Set the total number of missing noz-
zles for judging the nozzle check
NG . (*2)
COND.INDICATION (Refer to P.6-25 in this manual.) Displays the status of the NCU.
Pressing [FUNCTION] key, it dis-
plays every error that has occurred
in the NCU and between NCU ↔
Main Unit.
Using the [] or [] key, the errors
can be displayed one by one in the
order of occurrence.