Specifications

5-19
Troubles for which error messages are displayed
Error messages
Error messages indicates error numbers.
If any error message is displayed, turn off the power to the printer and turn it on after a while.
If the same error message appears again, contact your dealer or an office of MIMAKI to call for service.
Error message Cause Remedy
∗∗∗∗∗ ERROR 01 ∗∗∗∗∗
MAIN ROM
An error occurred in the circuit board
system.
Turn off the power to the printer and
turn it on after a while. If the same
error message appears again, contact
your local distributor to call for ser-
vice.
∗∗∗∗∗ ERROR 02 ∗∗∗∗∗
MAIN RAM
An error occurred in the circuit board
system.
∗∗∗∗∗ ERROR 03 ∗∗∗∗∗
POWER +3.3V
An error occurred in the circuit board
system.
∗∗∗∗∗ ERROR 03 ∗∗∗∗∗
POWER +5V
An error occurred in the circuit board
system.
∗∗∗∗∗ ERROR 03 ∗∗∗∗∗
POWER +24V
An error occurred in the circuit board
system.
∗∗∗∗∗ ERROR 03 ∗∗∗∗∗
POWER +42V
An error occurred in the circuit board
system.
∗∗∗∗∗ ERROR 04 ∗∗∗∗∗
F-ROM
An error occurred in the circuit board
system.
∗∗∗∗∗ ERROR 06 ∗∗∗∗∗
SD-RAM
An error occurred in the circuit board
system.
∗∗∗∗∗ ERROR 07 ∗∗∗∗∗
HEAD (----)
An error in heads was detected.
∗∗∗∗∗ ERROR 07 ∗∗∗∗∗
VOLTAGE (----)
An error in heads was detected.
∗∗∗∗∗ ERROR 08 ∗∗∗∗∗
LinearENCODER:SENSOR
An error occurred in the linear encoder.
∗∗∗∗∗ ERROR 08 ∗∗∗∗∗
LinearENCODER:DIR.
An error occurred in the linear encoder.
∗∗∗∗∗ ERROR 08 ∗∗∗∗∗
LinearENCODER:COUNT
An error occurred in detection by the
linear encoder.
(Read-out count error)
∗∗∗∗∗ ERROR 09 ∗∗∗∗∗
FPGA ERROR
An error occurred in the circuit board
system.
∗∗∗∗∗ ERROR 09 ∗∗∗∗∗
HDC ERROR (----)
An error occurred in the circuit board
system.
∗∗∗∗∗ ERROR 09 ∗∗∗∗∗
HEAT SINK (----)
Abnormal temperature is detected at
the control panel.
∗∗∗∗∗ ERROR 10 ∗∗∗∗∗
COMMAND ERROR
The printer received some data other
than command data.
Securely connect the interface cable in
position.
Use an interface cable conforming to
the specifications.
∗∗∗∗∗ ERROR 11 ∗∗∗∗∗
PARAMETER ERROR
Any parameter outside the range of
acceptable numeric values was
received.
Turn off the power to the printer and
turn it on after a while. If the same
error message appears again, contact
your local distributor to call for ser-
vice.