Specifications

6-21
Invoking MACHINE SETUP functions
PRE-FEED METHOD
Switch the operation method of pre-feeding.
Available setting values: [FORE (***mm), FORE&BACK]
When FORE (***mm) is set, a media is pre-feeded at specified amout, to remove the media that has waved
by the heat of the heater.
Change the feeding length of the media with [FUNCTION] key when FORE is selected.
Available setting values: [10 to 1000mm]
When FORE&BACK is set, a media is pre-feeded back and forth at specific amout, to avoid media stick-
ing.
HEATER SETUP
Set the temperature that determines whether the post-heater is reached to the specified temperature.
Available setting values: [STD, set -5°C, set -10°C, set -15°C, set -20°C]
When STD is set, this machine assumes the post-heater temperature has been reached when it reaches to
the specified temperature.
When Set -5°C, Set -10°C, Set -15°C, or Set -20°C is set, this machine assumes the post-heater tempera-
ture has been reached when the temperature is more than the set one subtracted the selected one.
Post-heater temperature easily lowers after printing.
In case of printing some data continuously with STD is set, if the temperature does not reach between com-
pletion of one data printing and a start of next printing, it displays “Temperature controlling.” It does not
start printing until the temperature reaches.
If you want to print continuously at low temperature, select other than STD.
MEDIA CUT
Set a key assignment for media cutting and the operation after cutting.
ASSIGN CUT KEY
Set whether to assign [] key to direct key of media cut.
Set Value: [ON, OFF]
When assigned to direct key, media cut is selected with [] key in the local mode, and when it is exe-
cuted, feeding is performed automatically until the printed image passes the cut line and then automatically
cut.
MOVE DROP MEDIA
Set the ejecting operation of a media on the platen after cutting.
Set Value: [ON, OFF]
When OFF is set, the media is not moved back and forth after cutting.
TIME SET
Set the date and time on the printer.
A past date and time up to 8 o’clock can be input.
If you have set a time in the future by mistake, the setting value can be returned to the previous setting
value by pressing the [FUNCTION] key. However, it is only the last previous setting value that the setting
made by mistake can be returned to.
The actually indicated last previous setting time is the last previous setting value plus the actually elapsed
time.