Specifications
6 Operation for Functions
6-20
BUILT-IN EXHAUST FAN
Set the operation of the built-in exhaust fan when the fan is equipped.
As a default, the built-in exhaust fan operates in conjunction with the dryness fan setting. If switched to
independent operation, different setting from the dryness fan is available.
STOP TIME
Set the time from the completion of printing to the stop of the fan.
Available setting values: [ CONT. , 0 ~ 240 min ] ( Default: 120 min [In steps of 1 minutes] )
[CONT.] means that the fan is always kept operating.
RENEW
Change fan operation. ( The fan motor operates according to the setting.)
Available setting values: [ON , OFF]
The setting is not stored in memory.
The built-in exhaust fan operates during printing and behaves according to the setting of the stop timer
after completion of printing.
SETUP INTERLOCK
Switch to the operation that is interlocked with the dryness fan setting.
DRYNESS FEED
Set whether or not to perform feeding for media drying.
Available setting values: [ON, OFF]
With DRYNESS FEED set to ON, the printer feeds the media up to the location of the post-heater where
the media is dried.
After waiting for a period of time that has been set by the setup Function (DRYING TIME - DRAWend),
the printer performs the next printing (media cutting). No back feed is performed. (Printing will be started
at the position to which the media has been fed for media drying.)
CONFIRM. FEED
Set whether or not to perform feeding the media after test printing for checking of the printing result.
Available setting values: [ON , OFF]
With CONFIRM. FEED set to ON, the media after completion of printing will be fed up to a position
where the print result can be checked on the platen.
In addition, when CONFIRM. FEED has been set to ON, [BACK FEED] can be set to ON using the
[FUNCTION] key.
The [BACK FEED] function returns to the original position the media that has been fed by the [CON-
FIRM. FEED] function.
Available setting values: [ON , OFF]