Specifications
2-11
Setting medias
2
Basic Operations
11
Hold the media with the media press
gently.
• Set the media so that no media sticks out from the
right end pinch roller to the right side.
• When using a thick media, remove the media
press from the media before printing.
12
Prepare the take-up device.
• When the Type B is used, the take-up device is
not equipped. Go to the Step 13.
( 1 ) Set an empty core of the roll media on the take-
up device.
( 2 ) Close the front cover.
13
Press the key to select “ROLL” .
• Detects the media width.
• When [MEDIA RESIDUAL] of the maintenance function is “ON” ( P.4-35), the screen for
entering media remaining amount is displayed after detecting the media width.
• Do not set media at the position which the media press touches the side plate on the right.
As media may tilt and be lifted, it could break the head.
•
If a media is misaligned to the right more than fixed position, a
warning is displayed. Set the media again.
Media press
***** ERROR 50 *****
MEDIA SET POSITION R
Media
Media Press
Side plate
on the right
Media press position:27 to 38 mm from the side plate on the right.
(For the variation of the inside diameter of media roll, it ranges as above.)
• Do not locate the suction hole on the platen between
the media and the media press. (It may stain the
media.)
Suction
hole
Front cover
Core
Take-up
device
MED I A SE L ECT
ROL L < > L EAF