Specifications

4-32
Setting Cleaning interval in Standby mode
This function is to be executed instead of TUBE WASH after the cleaning solution has been used up.
Set the cleaning type and the intervals at which cleaning operation is to be performed.
1
Select [ROUTINE SETUP] of the maintenance menu.
(1) Press the key in the local mode.
(2) Select [MAINTENANCE] by pressing the keys then press the key.
(3) Select [ROUTINE SETUP] by pressing the keys.
(4) Press the key.
2
Select [CLEANING] by pressing the
keys.
3
Press the key.
4
Set the cleaning interval by pressing
the keys.
Set valueÅFOFF, 1 - 168 hours
5
Press the key.
The selection display of the cleaning type is dis-
played.
6
Select the cleaning type by pressing
the keys.
Set value : NORMAL, SOFT, HARD
7
Press the key.
This function does not operate when the error message relating to ink, such as [NEAR END]
or [INK END], is displayed.
While this function is being executed, the display indicates the progress of head cleaning and
no key operation is available.(P.2-24 "Head Cleaning")
This function operates only when the machine is left with the display as shown below:
<LOCAL . 1> [ #01 ] *REMOTE. 1* [ #01]
0.00m
LOCAL mode REMOTE mode
ROUT I NE SETUP
CLEAN I NG <en t >
ROUT I NE SETUP
CLEAN . I NTERVAL =
1
h
ROUT I NE SETUP
CLEAN . I NTERVAL =
4
h
ROUT I NE SETUP
CLEAN . TYPE :
N
ORMAL
ROUT I NE SETUP
CLEAN . TYPE :
S
OFT
ROUT I NE SETUP
CLEAN . I NTERVAL =
4
h