Specifications
Overhaul of PCBs
3-19
3-4-1. Main PCB
Content
In changing Main PCB, parameters must be registered to Main PCB ROM after the change. Because of the time
it takes to readjust and reconfigure these settings, and for ease of use and better printing quality, copy the setting
value to a PC (upload) before replacement, then write the copied settings back to the main PCB from the PC
(download) after replacement.
Tools & jigs
•PC
•F/W UpdateTool
•USB Cable
Work Flow
Item Description
Reference
page
1. Upload Parameters Copy the setting values to a PC (upload) before replacing the main PCB. p.3-20
2. Remove/Install the main
PCB
Replace Main PCB
p.3-21
4. Download Parameters Write the parameter values that were uploaded in step 1 to the new main
PCB.
p.3-22
5. Adjust Main PCB Motor
Current
Adjust the power supply current value to reduce the hunting sound when the
X-axis motor and Y-axis motor are driven.
p.3-23
If upload of parameters is unavailable, conduct Parameter Draw to note the values. Then
manually register them after replacing the Main PCB.