PUMP MOTOR
Operation test of pump motor is executed.
Note: Be careful when executing (FORWARD) while the cap motor is on because this will become a vacuum suction..
TAKE-UP MOTOR
Operation test of take-up motor is executed.
HEATER TEST
Various tests of the media heater are executed.
Note1:Temperature is displayed with a unit selected in the UNIT SETUP of the MACHINE SETUP function.
Note2:A/D conversion value is also displayed.
<Pump motor test sequence>
No. Item Content Notice
1 Pump selection [], []: Pump selection (Move cursor)
[], []: Operation selection
[], []:
Selection of
item 1~3
2 Rotation direction
selection
[], []: Pump rotation direction selection
Set value: FORWARD, REVERSE
3 Driving speed
designation
[], []: Select driving speed
Set value: 100~4000 pps (unit: 100 pps)
4 Carriage/Motor
state selection
[FUNCTION]
: Carriage/motor state at test selection menu is displayed
<Carriage> IN: Execution at cap position / OUT: execution after carriage out
<Motor> ON: Execution with Y-axis motor ON / OFF:execution with Y-axis
motor OFF
5Test start
[ENTER]
: Cap OFF, carriage is moved to maintenance position. Pump motor is
driven with designated conditions.
[END]
:End
During
operation, open
and close the
cartridge valve
with the
[FUNCTION]
key.
6 Test end Test end
<Take-up motor test sequence>
No. Item Content Notice
1Test start
[ENTER]
: Take-up motor is driven
(Switching of winding direction, or operation stop is allowed
with SW of winding device)
2 Test end
[END]
:End
<Heater test>
Item Content
TEMPERATURE Control test of heater set temperature is executed.
Temperature settings of Pre, Print, After Heater are executed to control heater.
Set value (Celsius): OFF, 20 ~ 50 °C (unit: 1 °C)
Set value (Fahrenheit): OFF, 68 ~ 122 °F (as converted from celsius, unit is not 1°F)
SSR ON/OFF of heater is executed.
Heater is turned to ON/OFF according to ON/OFF designation of pre, print, after heater.
(Heater temperature control is not conducted)