ALL PATTERN
The following check patterns are drawn in the block.
MOTOR TEST
The following 6 motors are tested.
X SERVO MOTOR
Operation of X-servo motor is executed.
Note: During the test, heater temperature control is allowed (When HEATER key is effective).
Y SERVO MOTOR
Operation of Y-servo motor is executed.
Operation sequence is as same as that of X-axis motor test. (See the operation sequence above.)
Check pattern
Reference
page
Slant adjusting pattern P.3-10
Y-impact position adjusting pattern (FINE Y Bi) P. 3- 11
<Motor>
Motor name
Reference
page
X SERVO MOTOR P.2- 29
Y SERVO MOTOR P.2- 29
XY SERVO MOTOR P. 2- 3 0
WIPER MOTOR P. 2- 3 0
PUMP MOTOR P.2- 31
TAKE-UP MOTOR P. 2- 3 1
<X (Y)-servo motor test sequence>
No. Item Content Notice
1 Speed designation [], []: Speed selection set value
Set value: 1 ~ 150 mm/s (unit: 1 mm/s) (at X-axis motor test)
Set value: 1 ~ 1500 mm/s (unit: 1 mm/s) (at Y-axis motor test)
[], []:
Selection of item
2~4
2 Acceleration designation [], []: Acceleration selection
Set value: 0.01 ~ 0.50G (unit: 0.01 G) (at X-axis motor test)
Set value: 0.05 ~ 2.00G (unit: 0.05 G) (at Y-axis motor test)
3 Moving amount
designation
[], []: Moving amount selection
Set value: 1 mm ~ paper length (width) (unit: 1 mm)
When media is not detected X-axis motor: 1 mm~500000 mm
4 Cap OFF Only Y-moter
Only after media
detection
5Move
[ENTER]
: Reciprocating motion in the X (Y) direction with designated
conditions is repeated.
6 End
[END]
: Return to the motion starting position and execute capping to