Specifications

Color Inkjet Printer JV33-130/160
4-6
ERROR
25
FULL-SPEED An error occurred in
communication between
the host computer and
the interface board for
USB2.0 connection.
(Full-Speed mode con-
nection)
Check that the host PC supports the
USB2.0 interface. (Communication
can be resumed without changing any
setting. However, it is recommended to
use the connection in High-Speed
mode.)
Make sure that the host PC and the USB
cable follow the USB2.0 interface standard.
PACKET SIZE
OVER
An error occurred in
communication between
the host computer and
the interface board for
USB2.0 connection.
Make sure that the cables are con-
nected correctly and there is no occur-
rence of an error in the host PC.
1. Make sure that the connection to the host
PC is correct.
2. Make sure that there is no occurrence of an
error in the host PC, or the application runs
normally.
USB PROTOCOL An error occurred in
communication between
the host computer and
the interface board for
USB2.0 connection.
USB ENVIRON-
MENT
An error occurred in
communication between
the host computer and
the interface board for
USB2.0 connection.
USB DATA An error occurred in
communication between
the host computer and
the interface board for
USB2.0 connection.
ERROR
30
OPERATION
ERROR
Improper operation was
conducted on the opera-
tion panel.
Perform correct operations. 1. It is notified that wrong operation is con-
ducted.
ERROR
34
DATA REMAIN As received data which
is not drawn remains,
setting of Function Fea-
ture can not be changed.
Change setting function after executing
all received data or clearing the data.
1. Explain that any of the operating condi-
tions cannot be changed if data that have
not been drawn remains.
ERROR
40
MOTOR ALARM
X
The X-axis motor was
overloaded.
Turn the main power OFF and turn the
main power ON after elapse of 2~3
minutes. In a case of recurrence, con-
tact your local distributor to call for
service.
1. Check friction of X -axis motor.
2. Replace the X-axis motor with a new one.
3. Replace the regenerative resistance PCB
with a new one.
4. Replace the main PCB with a new one.
ERROR
41
MOTOR ALARM
Y
The Y-axis motor is
overloaded.
Turn the main power OFF and turn the
main power ON after elapse of 2~3
minutes.
In a case of recurrence, contact your
local distributor to call for service.
1. Check friction of Y-axis motor.
2. Replace the Y-axis motor with a new one.
3. Replace the regenerative resistance PCB
with a new one.
4. Replace the main PCB with a new one.
ERROR
42
X OVER CUR-
RENT
Overcurrent in the X-
axis motor was detected.
Turn the main power OFF and turn the
main power ON after elapse of 2~3
minutes.
In a case of recurrence, contact your
local distributor to call for service.
1. Check friction of X-axis motor.
2. Replace the X -axis motor with a new one.
3. Replace the regenerative resistance PCB
with a new one.
4. Replace the main PCB with a new one.
ERROR
43
Y OVER CUR-
RENT
Overcurrent in the Y-
axis motor was detected.
Turn the main power OFF and turn the
main power ON after elapse of 2~3
minutes. In a case of recurrence, con-
tact your local distributor to call for
service.
1. Check friction of Y-axis motor.
2. Replace the Y-axis motor with a new one.
3. Replace the regenerative resistance PCB
with a new one.
4. Replace the main PCB with a new one.
<Error messages and corrective measures (continued) >
Display
Cause
Remedy (instruction & maintenance manual)
ERROR
No.
ERROR
Descriptions in the manual
(for reference)
Remedy