Specifications
Troubles for which error messages are displayed
4-5
ERROR
08
LinearEN-
CODER: SENSOR
An error occurred in
detection by the linear
encoder.
(Counting impossible)
Turn the main power OFF and turn the
main power ON after elapse of 2~3
minutes. In a case of recurrence, con-
tact your local distributor to call for
service.
1. Make sure that linear encoder scale and
encoder PCB are placed in the right posi-
tions.
2. Replace the encoder PCB with a new one.
LinearEN-
CODER: DIR.
An error occurred in
detection by the linear
encoder.
(Wrong orientation)
LinearEN-
CODER: COUNT
An error occurred in
detection by the linear
encoder.
(Read-out count error)
ERROR
09
FPGA ERROR An error occurred on the
control circuit board.
(FPGA PDC)
Turn the main power OFF and turn the
main power ON after elapse of 2~3
minutes. In a case of recurrence, con-
tact your local distributor to call for
service.
1. Replace the main PCB with a new one.
HDC ERROR
(----)
An error occurred on the
control circuit board.
(FPGA HDC)
1. Replace the main PCB with a new one.
ERROR
10
COMMAND
ERROR
The printer received
some data other than
command data.
Securely connect the interface cable in
position.
Use an interface cable conforming to
the specifications.
1. When the state is not recovered even if
untreated data is cleared, execute the fol-
lowings.
2. Check the USB cable. (specifications,
cable length, etc.)
3. Replace the main PCB with a new one.
ERROR
11
PARAMETER
ERROR
Any parameter outside
the range of acceptable
numeric values was
received.
Turn the main power OFF and turn the
main power ON after elapse of 2~3
minutes. In a case of recurrence, con-
tact your local distributor to call for
service.
1. When the state is not recovered even if
untreated data is cleared, execute the fol-
lowings.
2. Check the USB cable. (specifications,
cable length, etc.)
3. Replace the main PCB with a new one.
ERROR
12
MAINTENANCE
COMMAND
– (This error does not occur on site.) 1. When the state is not recovered even if
untreated data is cleared, execute the fol-
lowings.
2. Check the USB cable. (specifications,
cable length, etc.)
3. Replace the main PCB with a new one.
ERROR
16
MRL COMMAND Received data does not
follow the command
system set in the device.
Transmit data with the command sys-
tem corresponding to the system.
1. Make sure that the transmission data is in
MRL-III command system (data ripped for
JV-33).
2. Check the command system set with
[MACHINE SETUP] - [MRL COM-
MAND].
<Error messages and corrective measures (continued) >
Display
Cause
Remedy (instruction & maintenance manual)
ERROR
No.
ERROR
Descriptions in the manual
(for reference)
Remedy