Specifications

- 4.15 -
Correcting the media feed rate during operation
In the “MEDIA COMP.”, operations are in a LOCAL mode.
The following describes the procedures altering the media feed rate during operation or
in the REMOTE mode. ( [MEDIA COMP.]
page 2.24).
STEPS:
1. Press the [REMOTE] key.
2. Press the [FUNCTION] key to confirm the
current setting value.
Press the [END] key when an appropriate value is set or to
abort an operation.
3. Press the [ENTER] key.
Available to alter the media feed rate.
4. Press the Jog key [ ] or [ ] as needed to set
the amount of correction.
The value is incremental/ decremental to the correction value
of the current media type.
•A new value takes effect in real time. The best
effect can be obtained while checking the result.
The unit of the correction value is the same as in
“MEDIA COMP.” in the LOCAL mode.
( page 2.24)
5. Press the [ENTER] key.
Confirm the media feed rate before saving it.
Press the [END] key to return to the REMOTE display.
The altered value ceases to be in effect, and returns to the
previous value.
6. Press the [ENTER] key to return to the RE-
MOTE display.
Save the altered media feed rate. The saved feed rate is
effective in the next power on. In case altering the setting on
the main unit, it displays “+” after the TYPE. Number.
Press the [END] key to save the value contemporary. Make
sure the value ceases to be in effect performing media
detection and invalid in the next power on.
REMOTE
TYPE. 1 0. 0 0m
FEED COMP.
0
FEED COMP.
0 0
FEED COMP.
0 1
correction value
current value
REMOTE
TYPE. 1+ 0. 0 0m
FEED COMP.
SAVE : ent