Setup guide
– 5.7 –
4) Select the item to be corrected using the
or key.
Start plotting with the
ENTER
key.
To enter the correction value without performing
plotting, press the
key.
When the
key is pressed, jogging can be
performed using the
, , and
keys. Store the origin with the
ENTER
key
and start plotting.
The waveform selected in Step 3 is displayed at
the right end of the first line.
V1:Variable-1 V2:Variable-2
N1:Normal-1 N2Normal-2
• “ADJUST: TEST DRAW” only plots
the test pattern that is used to check
the adjustments. There is no place
to enter correction values.
• If “ADJUST: FINE” is selected, refer
to the section “If FINE has been
selected” below.
• Enter such a value the right and left
protrusions of the plotted pattern
agree with each other.
5) When plotting has been completed, correction
value input mode is entered.
Input the values using the
and keys.
Then press
ENTER
key to enter the values.
In the follow way, enter the correction values for
between heads 1 and 2, and between heads 1 and
3.
6) Then, enter the following correction items in
the same manner.
•Y SINGLE
•Y REPEAT
•Y BI-D
#PRN. adjust2 V2
Adjust : Y Si.
#PRN. adjust2 V2
Adjust : Y Re.
#PRN. adjust2 V2
Adjust : Y Bi.
#PRN. adjust2 V2
Adjust : TSTprint.
#PRN. adjust2 V2
Adjust : FINE.
#PRN. adjust2 V2
Y Si. 1 - 2 : 0 . 0
#PRN. adjust2 V2
Y Si. 1 - 2 : 0 . 0