Setup guide
– 4.10 –
4-2-6. Replacement S-pump assy. (Periodical replacement)
CAUTION
• Be sure to wear protection glasses since you may get ink in your eyes.
If the ink sticks to your hand, the skin may be damaged.
[Parts to be used]
• S-pump assy. (M004868)
• Insulock (L60-100 mm)
[Adjusting procedure]
1) Remove instrumentation cover C at the back of the main unit.
2) Remove two tube clamps in the instrumentation case and then cut two insulocks for securing
the tube.
3) Remove the station cover.
4) Remove the suction side connection joint for the S-pump assy and S cap assy tube.
5) Take out the waste liquid side tube of the S-pump assy from the instrumentation case.
6) Remove the screw mounting S-pump assy and then replace new S-pump assy.
At the time of shipment,
The S-pump assy for Head 1,2 is based on double tube specification.
The S-pump assy for Head 3 is based on single tube specification.
The S-pump assy for Field replacement is based on double tube specification.
Suction side connection joint