Setup guide

– 4.6 –
4-2-3. Replacement S-Print head assy.
At the time of disassembling and assembling, do not loosen four head unit base
mounting screws unless the X position correction value exceeds ±8.
Be sure to perform [4-2-2. Washing a single S-print head assy] on page 4.5 for the
head for replacement.
[Disassembling procedure]
1) Turn ON the power of the device and then enter the ID of the head in advance.
2) Turn OFF the power supply switch, move the slider to the center of the platen.
3) Remove the front cover, the head cover and the head cover BKT.
4) Remove the head lever assy and the damper holder.
5) Remove the S-damper assy. of the S-print head to replace.
6) Remove the angle spring. Watch out for protrusion of springs.
7) Remove the screw (CS4 x 8SMW) from the S-print head assy. to replace.
8) Pull out the S-print head assy together with the damper holder to remove the FPC.
9) Replace the S-print head.
10) Fill up the ink.
11) Perform [FILL UP INK] in maintenance mode.
12) Check the normal discharge.
13) Perform [4-2-4. Adjustment of the head angle] (page 4.7) and [PRINT ADJUST2].