Setup guide
– 3.13 –
3-3-5. Fan motor
Problems The fan motor fails to turn.
The fan motor cannot be stopped running.
Causes 1) A part of motor cable has disconnected.
2) Clip the fan motor assy cable in the platen cover to short-circuit the fan
motor.
Checking procedures 1-2) Visually confirm the fun motor status.
([ACTION TEST - FAN MOTOR])
Remedies 1) Replace the fan motor assy. with a new one.
3-3-6. Abnormal nozzle discharge
Problems When checking the nozzle, the nozzle at the enter of the head does not print.
The edge of the nozzle does not print.
Causes 1) The amount of wiper contact is larger or smaller.
2) The capping position with respect to the head is not normal.
Checking procedure 1) Make visual check of the amount of wiper contact.
2) Perform the check test / the capping position.
(Refer to [6-6-2. Adjustment of the station position.])
Remedies 1) Adjust the amount of wiper contact.
2) Perform the adjustment of the station position.