Setup guide

– 3.3 –
3-2. Error messages and corrective measures
3-2-1. Error messages for troubles for which error numbers are given on the LCD
1) Replace the main PCB with a
new one.
1) Replace the power supply or
the main PCB with a new one.
1) Replace the main PCB with a
new one.
1) Has ink in the camper run out?
2) Replace the main PCB with a
new one.
3) Replace the head with a new one.
4) Replace the Slider PCB with a
new one.
1) Replace the Linear encoder
with a new one.
2) Replace the main PCB with a
new one.
1) Replace the main PCB with a
new one.
1) Check the data received
through HEX dump.
2) If error occurs at 1394
a. Check Time out of the
transfer tool (RIP).
b. Replace the I/F connection
board with [E102154A] or later.
c. Replace the 1394 board with
a new one.
d. Replace the main PCB with
a new one.
e. Supply power to the 1394
PCI board in the PC through
the power cable.
1) It is not used in the field.
The control ROM is in
abnormal conditions.
The control RAM is in
abnormal conditions.
The +5V (+35V) voltage is in
abnormal conditions.
The Flash memory is in
abnormal conditions.
An error has occurred in the
D-RAM.
Abnormal temperature is
detected.
The Linear encoder is in
abnormal conditions.
Configuration of PDC/IOC
has not been successfully
carried out.
•Configuration of HDC has not
been successfully carried out.
•Command code other than
MRL has been received.
Parameter that has not defined
in MRL has been received.
•A command error for
manufacture of has occurred.
Message Description
Corrective measures and
recovering procedures
ERROR01 MAIN ROM
ERROR02 MAIN RAM
ERROR03 POWER +5V
POWER +35V
ERROR04 FLASH ROM
ERROR06 D-RAM
ERROR07 TEMP n
ERROR08 ENCODER
ERROR09 HDC
ERROR10 COMMAND
ERROR11 PARAMETER
ERROR12 Ment Command