Setup guide

– 5.64 –
No. Indication Set value Description Remarks
23 N1BiADJ 0
24 N2BiADJ 0
25 V1HBiAJ 6
26 V2HBiAJ 4
27 RESERVE 0
28 RESERVE 0
29 RESERVE 0
30 WormORG 0
31 RESERVE 0
41 RESERVE 0
42 CUT.OVL 0
43 CUT.OVR 0
44 CUT.spd 0
45 RESERVE 0
46 QC3636 41
47 QC3654 41
48 QC3672 41
49 QC7272 41
50 QC1472 41
51 QC1414 298
52 FlashSW 1
53 PMPsign 0
54 RESERVE 0
55 Ext.CND 0
56 FEEDlow 30
57 PAGE 0
58 OEM
59 USE INK 0
60 MECAsiz 0
61 HASH 0
62 SUPPORT 0
63 INITIAL 0
Correction base value for N1 waveform Y direction shuttle movement
(in increments of 1 dot)
Correction base value for N2 waveform Y direction shuttle movement
(in increments of 1 dot)
Correction value for V1 waveform doubled shuttle movement
(in increments of 1 dot)
Correction base value for V2 waveform doubled shuttle movement
(in increments of 1 dot)
RESERVE
RESERVE
RESERVE
Worm origin
RESERVE
RESERVE
Medium cut over run (Left)
Medium cut over run (Right)
Cutting speed
RESERVE
Print Quality 360 x 360
Print Quality 360 x 540
Print Quality 360 x 720
Print Quality 720 x 720
Print Quality 1440 x 720
Print Quality 14400 x 1440
Periodical Flashing Switch
0: Disabled / 1: Enabled
Medium feed speed when
total feed is 9mm or more
Indicates the action when
the plot length exceeds
the page length.
0: JV3 / 1 : SPZ
0: RS ink
-1: RS ink of MS ink
1:
0: 54 inch
1: 63 inch
0: check pass
(forced startup)
1: check pass & survo
motor OFF
2: Released
3: Released + English
1: All parameters are
initialized.
2: Only system parameter
3: All parameters are
secret.
RESERVE
Command extension
Long direction feed rate (1mm/s)
Page length clip
0: The page length command is activated,and clipping is done
on the page.
n: The page length command is inactivated, the plot is plotted and
a margin is added at the rear end.
For OEM
INK type
Mechanical size
Hash check pass
Adjusting function extension
Initialization
When [1. All parameters are initialized] is selected for NO.63 INITIAL, note that
the values of the Adjustment parameter and Head parameter are also cleared.
REMOTE/LOCAL
+
FUNCTION
Adjusting function extension
ENTER
+ or + Enter the system parameter
REMOTE/LOCAL
Version up mode
+ Parameter UP&DOWN LOAD mode
0: normal (cm/s)
0: Disabled / 1: Enabled