Setup guide

– 5.63 –
5-5. #PARAMATER items
5-5-1. SYSTEM PARAMETER
[Function]
System parameter values are changed.
[System parameters list]
No. Indication Set value Description Remarks
0 COMP.X 0
1 COMP.Y 44
2R GRIP 0
3L GRIP 0
4 CAPpodY 20
5 PULLpos 25
6 FLSposY 0
7 WIPposY 35
8 RESERVE 0
9 CUTposi 0
10 EDGE LV 50
11 H12dist 252
12 H13dist 640
13 RESERVE 0 RESERVE
19 RESERVE 0 RESERVE
20 FEEDadj 25
21 V1BiADJ 0
22 V2BiADJ 0
Mechanical correction X
(in increments of 0.1 mm 500 mm – actual measured value)
Mechanical correction Y
(in increments of 0.1 mm 500 mm – actual measured value)
Adjustment of dead space on the right-hand side of the paper
(in increments of 0.1 mm 25 mm - actual measured value)
Adjustment of dead space on the left-hand side of the paper
(in increments of 0.1 mm 5 mm - actual measured value)
Adjustment of capping Y position (in increments of 0.1 mm)
Idle suction position (in increments of 0.1 mm)
Adjustment of flashing Y position (in increments of 0.1 mm)
Adjustment of wiping Y position (in increments of 0.1 mm)
RESERVE
Adjustment X of the medium cutting position
(in increments of 0.1 mm)
Medium edge detection level (Unit: %)
Distance between head 1/nozzle row A and head 2/nozzle row A
Distance between head 1/nozzle row A and head 2/nozzle row A
Adjustment of range
accuracy
If the system parameter
value is incrased:
Length of a pattern
plotted will be increased.
Adjustment value for
edge adjustment
If the system parameter
value is increased:
Dead space will be
reduced.
X feed pulse correction (in increments of 1 dot)
Correction base value for V1 waveform Y direction shuttle movement
(in increments of 1 dot)
Correction base value for V2 waveform Y direction shuttle movement
(in increments of 1 dot)
Adjustment value in the
X-direction when cutting
If the system parameter
value is increased:
Remaining portion of the
paper after cutting will
become larger.
Edge detection level
when the medium width
is detected