Setup guide

– 5.60 –
5-4-19. ENCODER CHECK
[Function]
Check linear sensor or linear encoder scale.
Based on capping position, indicate value of linear encoder and Y motor encoder when it’s
moved an optional position that was specified.
[Operation]
1) Select the TEST.
Press the
ENTER
key.
2) Select the “ENCODER CHECK” pressing the
FUNCTION
key.
Press the
ENTER
key.
3) Indicate the max movement distance that
carriage is moved.
4) Input the movement distance of carriage using
or key.
The value that is able to set up is decided 100
mm to max movement distance. (100 mm step)
5) Press the
ENTER
key
The carriage shuttles the set distance 3 times and
the linear encoder value and Y motor encoder
value are read.
Indicate the following values when carriage was
returned to capping position.
[value that is moved a specified distance]
– [value of capping position before movement]
M : value of Y motor encoder (µm)
E : value of linear encoder (mm)
FUNCTION
# TEST < ENT >
# TEST
ENCODER < ent >
#ENCODER
DIST . : . mm
#ENCODER
DIST . : . mm
#ENCODER
M . E .