Specifications

- 2.7 -
3. Adjust the height adjusting lever according to
the media to be used.
Set the height adjusting lever to the highest
stage or the lowest stage.
Setting it to the intermediate height, a plotting
fault can result.
4. Keeping the height adjusting lever held at the
aforementioned position, tighten the two
screws.
If you tighten the screws without keeping the
height adjusting lever held at the set position,
the head may not be secured at the normal
position.
Fasten the screw securely.
5. Return the carriage to the station position.
How to check of the head height
Check the head height as following procedure.
STEPS:
1. Make sure that the mode is LOCAL mode.
2. Press the [FUNCTION] key twice.
The head information is displayed.
3. Press the [END] key.
< LOCAL >
width : 1272 mm
Head Heigt
THIN
The head position is setted THIN.
Head Heigt
THICK
The head position is setted THICK.
Head Heigt
- - -
The error occurs.