Specifications

- 1.2 -
Moving the device
Where to install the device
Secure a suitable installation space before assembling the device.
The place of installation must have space required not only for the device itself but also for
plotting operation.
Model Width Depth Height Gross weight (with exhaust unit)
JV3-130SL 2390 mm 750 mm 1240 mm About 165kg
Working environmental temperature
This equipment should be used at 20-35
o
C to implement a stable print.
According to the surrounding temperature condition, the temperature may not rise to the
set value.
Precautions in installation
Do not install the device at the following environment.
3390 mm
500 mm
1000 mm
1000 mm
2750 mm
500 mm
A place exposed to
direct sunlight
A place in which temperature and
humidity vary by a great margin
Use the device under the following
environment.
Operating environment:
68 to 95
o
F (20 to 35°C)
35 to 65% (Rh)
A place exposed to direct air
blow from air conditioner, etc.
A place that is not
horizontal
A place that vibrates A place where fire is present