Specifications
2-9
2
Basic Operations
Test drawing
Make test drawing to check whether there is nozzle clogging or other drawing failures (such as wearing or
missing).
Execution of test drawing
1
Press the key in the local mode.
2
Press or key to select “NOZZLE CHK”.
• Select “HARDEN CHK” to confirm that UV ink has not been cured.
( P.4-42)
3
Press the key.
• Test drawing is started.
4
Test drawing ends
• Returned to the local mode.
• Execute operation of PXX, when evacuation of the Y-bar is required.
5
Check result of drawing
• When the result is normal, finish the operation.
• When the result is abnormal, execute head cleaning. ( P.2-10)
• Printing is disabled when the following messages are displayed. It is enabled when the
message has disappeared.
“WATER NOT READY” :The temperature of water in the hot water device has not
reached the predetermined value.
“UV NOT READY” : UV irradiation device is not ready.
Check before starting
test drawing
• Is media set ? ( P.2-5) • Is origin point set ?
• Is head gap value registered ? ( P.3-7)
Normal pattern
Abnormal patterns
Nozzle drop out Nozzle missing Deflection
TEST DRAW
NOZ Z L E CHK <ENT >
TEST
** TEST DRAW **
ENTER
Many lines are missing. The lines are missing as if
the teeth are lost.
The distance between the
lines is narrowing or
double lines are formed.