Specifications

5-5
Troubles for which error messages are given on the LCD
5
In Case of Trouble
Error message
Error messages indicates error numbers.
If any error message is given on the LCD, turn off the power to the device and turn it on after a while.
If the same error message appears again on the LCD, contact your local MIMAKI distributor or MIMAKI
office to call for service.
Error message Cause Corrective measure
Head connection can not be
confirmed.
Turn off the power to the device an
turn it on after a while.
If the same error message appears
again on the LCD, contact your local
distributor to call for service.
Head temperature can not be
read.
Data transmission speed is too
fast.
Control circuit board is
defective.
Data transmission speed is too
slow.
Control circuit board is
defective.
Battery shutoff is detected.
Contact your local distributor to call for
service.
Ink discharge is too late.
Turn off the power to the device an
turn it on after a while.
If the same error message appears
again on the LCD, contact your local
distributor to call for service.
Head setting failure.
Control circuit board is defective.
The device has received data
other than command data.
Securely connect the interface cable
in position.
Use an interface cable in
conformance with the standard.
A parameter outside the range of
acceptable numeric values is
received.
Check the host computer output
setting.
USB device initialization failure.
Turn off the power to the device an
turn it on after a while.
If the same error message appears
again on the LCD, contact your local
distributor to call for service.
Occurrence of a timeout error on
a USB device.
ERROR108
HD CONNECT : 12345678
ERROR108
HD THERM I S : 12345678
ERROR128
HDC F I FO OVER
ERROR128
HDC F I FO UNDER
ERROR129
BATTERY EXCHANGE
ERROR12A
HDS S PEED
ERROR12E
P-HEAD I NI T
ERROR12E
HEAD T I M I NG
ERROR132
CHECK : SDRAM
ERROR201
COMMAND
ERROR202
PARAMETER
ERROR304
USB I N I T ERR
ERROR305