Specifications
4-35
4
Daily Maintenance
Setting the UV lamp OFF duration
1
Select the “UV LAMP MODE” of the maintenance menu.
(1) Press the key in the local mode.
(2) Select the [MAINTENANCE] by pressing the or key, and press the key.
(3) Select the [UV LAMP] by pressing the or key.
(4) Press the key.
2
Select the [OFF TIMER] by pressing the
or key.
3
Press the key.
4
Select a set value by pressing the
or key.
•OFF:The UV lamp turns OFF at the set time automatically. (Default: 30 minutes).
ON :The UV lamp keeps ON state full-time.
Execute the operation of P.XX when OFF of the UV lamp is required.
• If “OFF” is selected, go to Procedure 5, if “ON” is selected, go to procedure 8.
5
Press the key.
6
Set the time duration to turn off the UV
lamp after the completion of drawing.
• OFF time can be set with time: minute. (Max. OFF after 23h59m duration)
(1) Input hour (0 to 23h) by pressing the or key.
(2) Move to setting of minute by pressing the key.
(3) Input minute (0 to 59m) by pressing the or key.
7
Press the key.
8
Press the key three times to finish.
FUNCTION
ENTER
ENTER
UV LAMP
OFF T I MER < e n t >
OFF T I MER
CONT . I RR .
:
ON
ENTER
OFF T I MER
CONT . I RR .
:
OFF
OFF T I MER
TIME: **h**m
ENTER
OFF T I MER
TIME: 01h00m
UV LAMP
OFF T I MER < e n t >
ENTER
END