Instruction manual

- 2.18 -
Displays the in-use setup type.
Displays the feed correct value type on drawing. (+/-)
[+] displays if the feed correct value is plus.
[-] displays if the feed correct value is minus.
The range for Y drawing (measure mm)
The range for X drawing (measure mm)
Print Mode V: Variable 1, 2 N: Normal 1, 2
Resolution 360x360, 360x540,
360x720, 720x720 (DPI)
Head height (measure mm)
Print Direction U, B (U=Unidirectional, B=Bidirectional)
Dividing method 2P, 3P, 4P, 6P, 8P, 12P, 16P
2H, 3H, 4H, 6H, 8H, 12H, 16H
(P:pass H: High speed print)
Print quality STD: Standard
FINE: Quality of image priority
FAST: Quality of speed priority
HOST: setting up drawing at the computer
Printing an image from source data
Starting the printing operation
The following describes the method of printing.
For various function settings necessary for printing, refer to “CHAPTER4 How to Set Functions”.
STEPS:
1. The machine enters the LOCAL mode.
2. Press the [REMOTE] key.
The machine enters the REMOTE mode.
3. Transmit data from the computer.
The plotting conditions that have been set for the data are
displayed.
For the method of data transmission, see the manual for the
output software.
When performing Discharge Composition drawing (when Discharge Composi-
tion for RIP software is available) and if “V720 x 720” is displayed for the
resolution, the range for Y drawing limits to 1,100 mm. Even if the data ex-
ceeds 1,100 mm is send, drawing will be performed up to 1,100 mm.
<< LOCAL >>
X =1010 Y = 1860
< REMOTE > TYPE
X=1010 Y=1860
< REMOTE >
360 x 360 / 4P / U
< REMOTE > V360x360
STD / 4P / U / .
< REMOTE > TYPE1 +
X=1010 Y=1860
Display them alternately