Owner manual

Axles Cab Service Rell Capacities
Front Fixed
Rear Oscillating
±13degrees
Maximum Single- 495 mm 19.5 in
Wheel Rise and Fall
Tires
Choose from a variety of tires to match
your application.
Choices include:
26.5R25 VLT BS E3 Radial
26.5R25 VJT BS E3/L3 Radial
26.5R25 VMT BS L3 Radial
26.5-25 SRG LD FS L3 Bias
750/65R25 XLD L3T MX L3 Radial
26.5R25 XHA2 MX L3 Radial
26.5R25 XLD D1 MX L4 Radial
26.5R25 VSNT BS E4/L4 Radial
26.5-25 SDT LD FS L5 Bias
26.5R25 VSDL BS L5 Radial
26.5R25 XLDD2 MX L5 Radial
26.5R25 X MINE D2 MX L5 Radial
Cat Flexport™
NOTE: In certain applications (such as
load and carry), the loader’s productive
capabilities might exceed the tires’ tonnes-
km/h (ton-mph) capabilities. Caterpillar
recommends that you consult a tire supplier
to evaluate all conditions before selecting a
tire model. Other special tires are available
on request.
ROPS/FOPS Meets SAE and
ISOstandards
Cat cab with a four post integrated Rollover
Protective Structure (ROPS) are standard in
North America and Europe.
ROPS meets SAE J1040 APR88 and
ISO3471:1994 criteria.
Falling Objects Protective Structure (FOPS)
meets SAE J231 JAN81 and ISO:1992
Level II criteria.
Sound
The sound values indicated below are
for specic operating conditions only.
Machineand operator sound levels will
vary at different engine and/or cooling fan
speeds. Hearing protection may be needed
when the machine is operated with a cabin
that is not properly maintained, or when
the doors and/or windows are open for
extended periods or in a noisy environment.
The operator sound pressure level for a
standard machine con guration, measured
according to the procedures speci ed in
ISO6396:2008, is 71 dB(A) with the
cooling fan speed set at maximum value.
The machine sound power level for a
standard machine con guration, measured
according to the procedures speci ed in
ISO6395:2008, is 111 dB(A) with the
cooling fan speed set at maximum value.
The machine sound pressure level for
a standard machine con guration,
measured according to the procedures
specied in SAE J88:2006, is 76 dB(A).
The measurement was conducted under
the following conditions: distance of 15 m
(49.2 ft), moving forward in an intermediate
gear ratio, static hydraulic cycle (with no
payload) and with the cooling fan speed
setat maximum value.
The operator sound pressure level for
a machine installed with a Low Sound
package, measured according to the
procedures specied in ISO6396:2008,
is69dB(A) with the cooling fan speed
setatmaximum value.
The machine sound power level for a
machine installed with a Low Sound
package, measured according to the
procedures specied in ISO6396:2008,
is108dB(A) with the cooling fan speed
setatmaximum value.
Fuel Tank – 381 L 101 gal
Standard
Cooling System 65 L 17.2 gal
Crankcase 24.5 L 6.5 gal
Transmission 50 L 13.2 gal
Differentials and 64 L 16.9 gal
Final Drives – Front
Differentials and 64 L 16.9 gal
Final Drives – Rear
Hydraulic Tank 198 L 52.3 gal
15