Instruction manual

TROUBLESHOOTING
message diagnosis action
E1 (program) security code required enter access code into P000
E2 (run) totalizer resolution too low increase value (P631 - P639)
E3 (run) zero out of range consider an initial zero P377,
refer to Recalibration\Initial Zero
E4 (run) span out of range consider an initial span P388,
refer to Recalibration\Initial Span
E5 (run) parameter not entered check parameters P005 - P017
for entry
E6 (run) zero calibration required do a zero calibration
E7 (run) span calibration required do a span calibration
E8 (program) parameter value error check that value is valid
E9(run) auto zero out of range auto zero has accumulated
deviation beyond 2% from
last operator initial zero. If
error is not caused by material
on belt, then do an operator
initiated zero.
E10 (run) rate or span out of range loading on belt is 300% of
rated load or greater.
Investigate and if no mechanical
cause, check to see if re-rating
the design rate is required.
E11 (run) speed greater than twice check design belt speed against
the design speed actual belt speed,check speed
constant, perform speed constant
adjust (P018) if necessary.
E12 (factoring) span out of range test load is either too low or
beyond 100% of design load
(P952). Replace test weight with
a heavier or lighter weight and try
factoring again.
E101 (run) load cell ’A’ check wiring
E102 (run) load cell ’B’ check wiring
APPENDICES
PL-531 80