Instruction manual

Linearization Parameters, P390 - P396
These parameters are used to compensate for non-linear response of the weighing
system to the BW100. Refer to Recalibration\Linearization for details and example on
the use of these parameters.
P390 linearization
Enables or disables the linearization function.
entry: 0 = off
1 = on
P391 linearizer, point 1
enter the load, in units of P017, for point 1
P392 compensation, point 1
enter the calculated compensation, in percent, for compensation point 1
P393 linearizer, point 2
enter the load, in units of P017, for point 2
P394 compensation, point 2
enter the calculated compensation, in percent, for compensation point 2
P395 linearizer, point 3
enter the load, in units of P017, for point 3
P396 compensation, point 3
enter the calculated compensation, in percent, for compensation point 3
End of Linearization Parameters.
PARAMETER DESC.
PL-531 67