MESSAGE REQUESTS
Message requests must be transmitted from the host to the BW100 in the
following format.
som DEVICE MT eom
Example:
Data ASCII Example
Field Character Description
som STX start of message
DEVICE 01 for BW100 # 1
MT 50 material flow rate request
eom CR end of message
MESSAGE RESPONSES
The BW100 response to a flow rate (MT=50) load (MT=51) or speed (MT=52)
message request is in the following format.
som DEVICE MT READING eom
Example:
Data ASCII Example
Field Character Description
som STX start of message
DEVICE 00 from BW100 # 0
MT 50 material flow rate response
READING 392.5 is 392.5
eom CR end of message
The response to a material total (MT=53) message request is in the following format.
som DEVICE MT READING UNITS eom
Example:
Data ASCII Example
Field Character Description
som STX start of message
DEVICE 01 from BW100 # 1
MT 53 material total response
READING 129.2 is 129.2
UNITS t metric tonnes
eom CR end of message
OPERATION