Specification Sheet

SAFETY DATA SHEET
according to Regulation (EC) No. 1907/2006
Catalogue No.
101298
Product name
Coliforms 100 Readycult®
The Safety Data Sheets for catalogue items are available at www.merckgroup.com
Page 5 of 10
Glove thickness:
0.11 mm
Break through time:
> 480 min
The protective gloves to be used must comply with the specifications of EC Directive
89/686/EEC and the related standard EN374, for example KCL 741 Dermatril® L (full contact),
KCL 741 Dermatril® L (splash contact).
The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374
with samples of the recommended glove types.
This recommendation applies only to the product stated in the safety data sheet<(>,<)> supplied
by us and for the designated use. When dissolving in or mixing with other substances and under
conditions deviating from those stated in EN374 please contact the supplier of CE-approved
gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Respiratory protection
required when dusts are generated.
Recommended Filter type: Filter P 1 (acc. to DIN 3181) for solid particles of inert substances
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective
devices are carried out according to the instructions of the producer. These measures have to be
properly documented.
Environmental exposure controls
Do not empty into drains.
SECTION 9. Physical and chemical properties
9.1 Information on basic physical and chemical properties
Form
granular
Colour
light brown
Odour
peptone-like
Odour Threshold
No information available.
pH
6.6 - 7.0
at 17 g/l
25 °C