Specifications
Heavy-Duty Hydraulic Cylinders
HV2 Series
Catalog HY08-M1140-3/NA
66
www.milleruidpower.com
Miller Fluid Power
Des Plaines, IL
Milton, Ontario Canada
End of Stroke Magnetic Principle Type
Proximity Switch
Reliable: Proximity type sensor never contacts cylinder
moving parts; eliminating wear and adjustments.
Positive Action: Multiple magnet design provides “snap
action.” Eliminates creep and false signals.
Versatile: Sealed stainless steel switch body can be used
with any operating uid and is impervious to most environmental
conditions.
OPERATING PRINCIPLE
Sensing
Area
Sensing
Distance
Magnet Ass’y
Switch Case
N/O
N/C
Com.
Unoperated
N
Ferrous
Actuator
Differential
Connecting Rod
N/O
N/C
Com.
Operated
N
Switch Options
Quick disconnect.
Explosion proof.
Sub sea, to 2000 feet depths.
Extra-long leads.
As shown in the sketches above, these
switches are magnetically operated. Dual
magnets provide a dependable “snap action”
for positive position sensing.
In the “unoperated” position, the magnet
assembly is attracted in the direction of the
arrow, causing a nely ground stainless steel
connecting rod to hold the contacts open.
In the “operated” position a ferrous part
(cushion or piston) enters the sensing area
and attracts the magnet assembly which
causes the rod to draw the contacts closed.
How to Order:
To order switches, enter a “9” in the Modied
eld of the cylinder model code. Describe the
modication in notes by specifying:
1
. Magnetic end of stroke switch
2. Installation in head, cap, or both ends
of the cylinder
3. Location in the head or cap (position #1,
2, 3, or 4) not occupied by a port or
mounting
End-of-Stroke Switch
Bore Rod Dia. HR HB
1.50
0.625 2.56
3.25
1.000 2.75
2.00
1.000 2.56
3.00
1.375 2.75
2.50
1.000 2.31
2.751.375 2.50
1.750 2.75
3.25
1.375 2.94
2.501.750 3.13
2.000 3.31
4.00
1.750 2.88
2.442.000 3.06
2.500 2.44
5.00
2.000 2.31
3.25
2.500 2.63
3.000 2.88
3.500 3.13
6.00
2.500 2.13
1.44
3.000 2.38
3.500 2.63
4.000 2.88
7.00
3.000 3.38
2.63
3.500 2.13
4.000 2.38
4.500 2.63
5.000 2.94
8.00
3.500 3.13
2.25
4.000 3.38
4.500 3.63
5.000 2.44
5.500 2.75
Switch Height
Specications
Switch Type:
Magnetic Principle
Contacts:
Single Pole-Double Throw (SPDT)
Contact Rating
1
:
2 Amp at 110-240 VAC (UL & CSA) 100
MA at 12 VDC 50 MA at 24 VDC (CSA)
Note: Check current draw of
solenoid valves.
Connection: 36" long, 3 wire, potted
in cable. Can be wired Normally Open
or Normally Closed. Leads are tagged
(Com, N/O, N/C)
Pressure Rating: 3000 PSI
Non Shock
Temperature Range:
-
20°F to + 200°F (UL 104°F. Max.)
Sensing Gap:
.030 to .060 inch
Trip Point: Factory Set with Piston
Bottomed out
Release Point: Approximately 0.25"
Piston Travel
Min. Cyl. stroke 0.50" on 1.50" & 2.00"
bore, 0.75" stroke on 2.50" and up.
1
UL and CSA approved for industrial
control, general purpose use. If
Class I, Division 1 or 2 is required,
please specify.