Specifications
Compact Hydraulic Cylinders
Series CHD
Catalog HY08-M1137-3/NA
22
www.millerfluidpower.com
Miller Fluid Power
Des Plaines, IL
Milton, Ontario Canada
T Mount – Single Rod End
T Mount Single Rod End – Envelope and Mounting Dimensions
Rod End Dimensions
Thread Style 8
Thread Style 9Thread Style 4
“Special”
Thread Style 3
Special thread,
extension, rod
eye, blank, etc.
are also available.
To order, specify
“Style 3” and
give desired
dimensions for
KK, A, & W.
If otherwise
special furnish
dimensional
sketch.
Style 55
T Mount Single Rod End – Rod Dimensions
Style T Through Bolt Mount – Single Rod End – 20mm to 80mm Bore Size
D
WRENCH
FLATS
KK
WA
Ø NA
C
Ø MM
D
WRENCH
FLATS
CC
Ø NA
A W
C
Ø MM
D
WRENCH
FLATS
Ø MM
Ø NA
KK
C
W
A
Ø AF
WAD
AE
Ø AM Ø MM
W
ZJ + STROKE
Ø MM
EL EL
2X EE
EK
EK
LB + STROKE
R
(SQ.)
E
(SQ.)
4X Ø FB THRU
Ø FC COUNTERBORE
x FD DEEP BOTH ENDS
Bore
Ø
E EE EK EL FB FC FD R W Add Stroke
SAE NPTF BSP LB ZJ
20
44 #2
1
1/8 G-1/8 6 16.5 5.5 9.5 5.4 30 8 43 51
25 50 #2
1
1/8 G-1/8 8 17.5 5.5 9.5 5.4 36 8 45 53
32 62 #4 1/4 G-1/4 11 20.5 7 11 6.5 47 10 51 61
40 70 #4 1/4 G-1/4 12 21 9 14 8.6 52 10 55 65
50 80 #4 1/4 G-1/4 14 22.5 11 17.5 10.8 58 11 60 71
63 94 #4 1/4 G-1/4 17 26 13.5 20 13 69 13 67 80
80 114 #6 3/8 G-3/8 20 29.5 16 23 15.2 86 17 78 95
Bore
Ø
MM
Rod
Ø
Rod Thread Rod Extension
Dimensions
Style 9M Style 4M Style 9A Style 4A Style 8A Style 55M
KK A KK A KK A KK A CC A AD AE AF AM C D NA
20 12 M8x1.25
10 M8x1 14 5/16-24 10 5/16-24 14 3/8-24 16 8 3 6 11 6 10 11
25
14 M10x1.5 12 M10x1.25 16 3/8-24 12 3/8-24 16 1/2-20 18 12 4 8 13 6 12 13
32
18 M12x1.75 15 M12x1.25 18 7/16-20 15 7/16-20 18 9/16-18 25 16 6 10 16 8 15 17
40 22 M16x2 20 M16x1.5 22 5/8-18 20 5/8-18 22 3/4-16 30 20 8 12 20 8 19 21
50 28 M20x2.5 24 M20x1.5 28 3/4-16 24 3/4-16 28 7/8-14 35 24 10 16 25 9 24 27
63 36 M27x3 30 M27x2 36 1-14 30 1-14 36 1 1/4-12 45 28 12 22 33 11 32 35
80 45 M33x3.5 35 M33x2 45 1 1/4-12 35 1 1/4-12 45 1 1/2-12 56 34 14 28 41 13 39 43
1
Parker Triple-Lok
®
Straight Thread Connector SAE #2 to ¼" 37° flare can be used when this port thread is required.