Specifications

Compact Hydraulic Cylinders
Series CHE
Catalog HY08-M1137-3/NA
19
www.millerfluidpower.com
Miller Fluid Power
Des Plaines, IL
Milton, Ontario Canada
Switch Mounting / End-of-Stroke Location
1. Slide the switch into any of the six mounting grooves
provided.
2. For end of stroke sensing, position cross hairs of
target symbol on the switch at the specified
distance from the cylinder body end as listed in the
table below.
3. Locate the switch as required for intermediate stroke
position sensing.
4. Turn the locking screw clockwise to secure the switch
in place.
A
31.5
B
31.5
B
A
‘V’ NOTCH
1
Switch Location for End-of-Stroke Sensing
1
The rod side for switch location ‘B’, on double rod end cylinders, is identified by a ‘V’ notch in the ‘NA
diameter of rod end styles #4, #8, and #9. The ‘V’ notch will be in the ‘AM’ diameter of rod end style #55.
Minimum Stroke for Cylinders with Switches
All Bores
One Switch Two Switches
5mm 10mm
Bore A B
20
18.5 24
25
19.5 25
32 22.5 28
40 23.5 31
50 26 33.5
63 29.5 37
80 35 42.5
100 42.5 53