Owner`s manual

OM-172 324 Page 65
11-2. Setting Rise Time
Maximum Rise Time setting will make the welding power source go to its
maximum output.
NOTE
1 Rise Time Display
Setting is depend on desired arc
characteristics. Make a sample
weld after each setting until desired
arc characteristics are obtained.
Use Increase or decrease button to
change setting.
Range is 250 to 1250 A/ms.
Press Reset button to save setting
and exit Control menu.
1
> 255 A/ms
Access
Control
Display
>Ri se Time >1250 A/ms
Increase/Decrease
Reset
>P r o c e s s
Sequence
Ca r d
>P r g 1
Pu l se
035 Steel
Argon Oxy