Owner`s manual

OM-172 324 Page 63
10-22.Arc Voltage Error Selection
1 Monitor Display
Provides a means to enable/dis-
able the arc voltage error feature
and to set an acceptable range of
deviation from set arc voltage or arc
length (trim) before the error will ac-
tuate.
When this feature is off, arc voltage
or arc length variations will not
cause an error or shut the unit
down.
When this feature is on and a range
of deviation is set (±0.1 9.9 volts
from desired weld voltage), arc volt-
age or arc length variations outside
of the range for a period of time
longer than that set by the Arc Error
timer, causes either the error relay
to energize or the unit to shut down
depending on the Arc Start/Volt
Sense shutdown error setting.
Robot
Arc Fai l
>Mo n i t o r
So f twar e
Ar c V o l t s
>O n
2.0 Vol ts
1.0 Sec
Arc Vol ts
>O f f
1
Press
Mode Select
Increase
Access
Setup
Display
When a system reset is done, Monitor is set to Off.
10-23.Software Version Number
1 Example Version Number Dis-
play
When talking with service person-
nel, this number may be required.
(Check actual unit display for num-
ber.) The factory keeps this number
on file with the serial number of the
unit.
1
Robot
Arc Fai l
Mo n i t o r
>S o f t w a r e
Ve r s i o n
#123456Z
Press
Mode Select
Access
Setup
Display