Owner`s manual

OM-172 324 Page 48
9-3. Naming Programs And Writing To Card
All program types (Pulse, Adaptive Pulse, and MIG) can be stored on a data card
and retrieved.
NOTE
1 Card Display
Use Mode Select button to select
Card.
2 Moving Line
Moving line is under value that can
be changed. Use increase or
decrease button to change value.
3 Name Display
If no name is desired, press
Parameter Select button to contin-
ue the write procedure.
Process
>C a r d
Sequence Press
Be l ow
>Wr i t e
Read
De l e t e
Done
#1 Pu l se
035 Steel
Argon Oxy
Press
Name? No
035 Steel
Argon Oxy
Press
Name? Yes
5007992
Frame _
Press
Wr i teDone
Prg 1 to
Ca r dPr g 1
Press
#1 Pu l se
035 Steel
Argon Oxy
Press
Name? Ye s
035 Steel
Argon Oxy
Press
Name? Yes
0 35 Steel
Argon Oxy
Press
Name? Ye s
5007992
Frame
Press
Wr i teDone
Prg1 to
Ca r d P r g1
Press
#1 Pu l se
5007992
Frame
Press
1
2
3
Increase
Parameter
Select
Parameter
Select
Parameter
Select
Parameter
Select
Name? No
5007992
Frame
Press
Parameter
Select
Increase
Parameter
Select
Parameter
Select
Parameter
Select
Yes
No
Increase/
Decrease
Allowable characters include: 0 thru 9, :, ;, <, =,
>, ?, @, A thru Z, [, , ], ^, _,, a thru z , blank , !, ,
#, $, %, &, , (, ), *, +, , ., /,