Owner`s manual

OM-172 324 Page 38
7-4. Setting Teach Point Parameters On The Pulse Panel
Pu l se
035 Steel
Argon-Oxy
>T e a c h O f f
When the Process Teach mode is On, and
one of the following pulse parameters is se-
lected: ApK, AbK, PPS, or PWms, the pulse
panel displays the selected pulse parameter
instead of Trim (arc length). When the pulse
parameter is selected, the value can be
changed with the pulse panel controls as fol-
lows:
1 ApK Display
2 AbK Display
3 PPS Display
4 PWms Display
When values have been set for a teach point,
strike and maintain an arc for five seconds.
Repeat procedure at each teach point until
custom program is complete (see Section
7-2).
Turn Teach mode Off.
5 Custom Pulse Screen
The letter C will appear in the upper right cor-
ner of all customized programs.
Customized programs can be reverted back
to factory-set values through memory reset
(see Section 10-15).
>P r o c e s s
Ca r d
Sequence
Parameter
Parameter
Select
450 IPM
343 Apk
>70 Abk
160 PPS
Teach On
450 IPM
>3 4 3 Apk
70 Abk
Select
1
Increase/
Decrease
Increase/
Decrease
Parameter
Select
Or
Parameter
Select
Increase/
Decrease
Increase/
Decrease
Parameter
Select
Prg1 C
Pu l se
035 Steel
Argon-Oxy
3
Parameter
Select
>T e a c h O n
450 IPM
343 Apk
92 Abk
Teach On
450 IPM
>3 4 0 Apk
70 Abk
Increase/
Decrease
450 IPM
343 Apk
>92 Abk
160 PPS
343 Apk
92 Abk
>1 6 0 PPS
1.9 PWms
343 Apk
92 Abk
>2 8 0 PPS
1.9 PWms
343 Apk
92 Abk
280 PPS
>1 . 9 PWms
343 Apk
92 Abk
280 PPS
>3 . 6 PWms
Teach On
>4 5 0 IPM
340 Apk
70 Abk
2
4
5
Weld for
5 seconds