OM-172 324 Page 18
4-9. Control Settings On Invision 456P Inverter Model Welding Power Source
Set controls as shown for all
welding processes when
using this interface unit.
1 Voltage Adjustment Control
2 Inductance Control
Inductance determines the “wetness” of the
weld puddle. When set higher, “wetness”
(puddle fluidity) increases.
3 Remote On/Off Receptacle (Optional)
Sockets 1 and 2 are connected in parallel
with the Power On/Off switch. For remote
On/Off control, connect a suitable plug from
a remote switch to the receptacle and place
front panel Power On/Off switch in Off posi-
tion. Unit can then be turned On and Off
through the use of the remote switch.
1
2
ST-801 718 / ST-180 311-B
3