Owner`s manual
OM-172 324 Page 16
4-7. Control Settings On Dimension 452 Or 652 Ampere Model Welding Power Source
ST-800 166-B / Ref. ST-161 964-A
Set controls as shown for all
welding processes when us-
ing this interface unit.
1 Arc Force (Dig) Control
2 Hot Start Switch
3 Amperage/Voltage Adjustment
Control
Setting at controls and switch posi-
tion does not matter when Process
Selector switch is in GMAW posi-
tion and remote Amperage/Voltage
Control switch is in REMOTE posi-
tion.
ST-800 091 / ST-162 500-A
132
12
14
16
18
20
22
24
26
28
30
32
34
36
1
Set switches as shown for all
welding processes when us-
ing this interface unit.
1 Arc Force (Dig) Control
2 Amperage/Voltage Adjustment
Control
Setting at controls does not matter
when Process Selector switch is in
GMAW position and remote Am-
perage/Voltage Control switch is in
REMOTE position.
2
Dimension 452 Model
Dimension 652 Model