6. Calibrate STICK voltage as follows:
a. Connect voltmeter from STICK stud (front left) to Work stud (front center).
b. Press memory 3 button on the power source front panel. Open circuit voltage should now be present from STICK output stud to the Work
stud.
c. Using the knob on the power source front panel, set the display voltage to the measured value on the voltmeter.
d. Press memory 3 button on the power source front panel to end the STICK voltage calibration.
e. Power source will display CAL.
7. Calibrate amperage as follows:
a. Connect shorting cable from STICK stud (front left) to Work stud (front center).
b. Attach clamp-on ammeter around shorting cable.
c. Press memory 4 button on the power source front panel. Amperage should now be flowing in the shorting cable.
d. Using the knob on the power source front panel, set the display amperage to the measured value on the ammeter.
e. Press memory 4 button on the power source front panel to end the amperage calibration.
f. Power source will display CAL.
g. Disconnect shorting cable.
8. Remove Calibration card as follows:
a. Lift and hold memory card access cover open.
b. Push in and release memory card to eject card.
c. Grasp memory card and remove from slot.
d. Close memory card access cover.
9. Turn off power to the welding system.