Owner`s manual
OM-2226 Page 55
B. Lockout Levels
Level 1
NOTE: Before activating lock out
levels, be sure that all procedures
and parameters are established.
Parameter adjustment is limited
while lock out levels are active.
NOTE: Remote amperage control
is not available in level 1.
TIG Output Selection
If either the TIG Impulse HF or TIG
Lift Arc process (see Section 4-7)
was active when lockout level 1
was activated, the operator can
choose between RMT STD (Re-
mote Standard) or RMT 2T HOLD
(Remote 2T Hold). The On function
is also available if TIG Lift Arc was
active.
If RMT 2T was reconfigured (see
Section 4-14) prior to lockout level
1 activation, the reconfigured out-
put mode (4T, 4T momentary, mini
logic, or spot) is available to the op-
erator instead of RMT 2T.
Stick Output Selection
If the Stick process was active
when lockout level 1 was activated,
the operator can choose between
RMT STD or On.
Process selection may not be
changed in lockout level 1. If the op-
erator tries to change his process
selection, the amperage (right) me-
ter will display [LĆ1]
as a reminder.
The parameters for the remaining
functions may be viewed by press-
ing the appropriate switch pads. If
the Encoder is turned while viewing
parameters, [LĆ1] will be displayed,
and parameters will not change. If
unit is equipped with a pulser and
the pulser is off, [LĆ1] will be dis-
played as a reminder that the pulser
is off.
Level 2
NOTE: Before activating lockout
levels, be sure that all procedures
and parameters are established.
Parameter adjustment is limited
while lockout levels are active.
NOTE: Remote amperage control
is not available in level 2.
Includes all the functions of level 1
plus Process Selection (see Sec-
tion 4-4).
For The Stick Process
Process Selection
Level 1
Level 2
Use Output Switch Pad To
Select A Trigger Method
For The TIG Process
Select Stick, Or Lift-Arc,
Or HF Start
Use Output Switch Pad To
Select A Trigger Method