Owner`s manual

OM-2226 Page 52
4-19. Arc Timer/Counter Display (All Models)
1 Output And Amperage Controls
2 Power Switch
To display the arc timer/counter, turn pow-
er off. Push and hold Output and Amper-
age control switch pads, and turn On
Power switch. Hold switch pads for
approximately 7 seconds (or until soft-
ware version number
_ _ _ _ _ _-_clears displays).
3 Arc Timer Display
Upon power up as described above, the
S LED will turn on, and arc time will be dis-
played for 5 seconds as [000 000] to [999
999]. The first four numbers indicate
hours, and the last two numbers indicate
minutes. Arc time shown in example is
read as 1,234 hours and 56 minutes. Max-
imum arc time is 9,999 hours and 59 min-
utes.
4 Arc Counter
After 5 seconds, the A LED turns on, and
the arc counter will be displayed for the
next 5 seconds as [000 000] to [999 999).
The maximum arc cycle count is 999 999.
Rear Panel
2
V
And
1
Non CE Models
1
123 456
3/4
Or