Owner`s manual
OM-2226 Page 49
4-16. Mini Logic Operation (DX, LX And All CE Models)
1 Mini Logic Meter Display
Sequencer option required to re-
configure for Mini Logic.
Select Mini Logic according to Sec-
tion 4-14.
Torch trigger operation is as shown.
During Mini Logic welding opera-
tion, the weld current can be
toggled between the initial amps
level and the weld amps or slope
level by pressing and releasing the
torch trigger in less than 3/4 sec-
onds.
During Mini Logic, Final Amperage
is not available. Final slope will al-
ways slope to minimum amperage
and end the cycle.
NOTE: When a remote switch is
connected to the welding power
source, only trigger input is func-
tional. Amperage is controlled by
the welding power source.
Application: This ability to change
current levels without either initial
slope or final slope, gives the oper-
ator the opportunity to adjust filler
metal without breaking the arc.
=
SEL H4L
Mini Logic
1
Preflow
Initial Amps
Initial Slope
Final Slope
Postflow
Weld Amps
Push & Hold
Trigger For More
Than 3/4 Sec.
Torch Trigger Operation
Release Trigger
Final Slope
Rate
Push & Release
Trigger In Less
Than 3/4 Sec.
Final Slope
Rate
Initial Amps
Push & Release
Trigger In Less
Than 3/4 Sec.
Push & Hold
Trigger For More
Than 3/4 Sec.
Push & Release
Trigger In Less
Than 3/4 Sec.
Push And Hold
Trigger For More
Than 3/4 Sec.
Push & Hold
Trigger For More
Than 3/4 Sec.
Push & Hold
Trigger
Push & Release
Trigger In Less
Than 3/4 Sec.
NOTE: If arc is broken and trigger is depressed, or trigger is still depressed after postflow time is complete, HLP-10 will be displayed (see
Section 5-3).