Owner`s manual

OM-2226 Page 48
4-15. 4T Specific Trigger Method (DX, LX And All CE Models)
1 4T (Specific Trigger
Operation)
Sequencer is required to reconfi-
gure for 4T.
Select 4T according to Section
4-14.
Torch trigger operation is as shown.
While in 4T mode, there is a func-
tion available during the main weld
sequence that allows the operator
to toggle between weld current and
final current without breaking the
arc.
NOTE: When a remote switch is
connected to the welding power
source, only trigger input is func-
tional. Amperage is controlled by
the welding power source.
Application:
Use 4T trigger method when the
functions of a remote current con-
trol are desired, but only a remote
on/off control is available.
=
SEL H-4
4T
Current (A)
Preflow
Initial Amps
Initial Slope
Final Slope
Postflow
Push & Hold
Trigger
Release
Trigger
Push & Hold
Trigger
Release
Trigger
Push & Release
Trigger In Less
Than 3/4 Sec.
Weld Amps
Final Amps
Torch Trigger Operation
Push & Release
Trigger In Less
Than 3/4 Sec.
1
NOTE: If arc is broken and trigger is depressed, or trigger is still depressed after postflow time is complete, HLP-10 will be displayed (see
Section 5-3).