Owner`s manual

OM-2226 Page 44
4-14. Reconfiguring 2T For 4T, 4T Momentary, Mini Logic Control, Or Spot (DX, LX And All
CE Models)
1 Process Switch Pad
2 Output Switch Pad
3 Power Switch
To reconfigure 2T, turn power off. Push
and hold the Process and Output
switch pads and turn On power switch.
Hold switch pads for approximately 7
seconds (or until software version
number _ _ _ _ _ _-_clears, and display
reads [SEL] [H-2).
4 Encoder Control
Use Encoder to change functions. Ac-
tive function will be displayed on am-
perage (right) meter.
5 Parameter Displays
The displays for the different functions
will be as shown.
Press torch trigger or turn power Off to
save setting.
Proceed to Section 4-15 for 4T, [SEL]
[H-4), operation. Sequencer option re-
quired to reconfigure for 4T.
Proceed to Section 4-16 for Mini Logic,
[SEL] [H4L), operation. Sequencer option
required to reconfigure for Mini Logic.
Proceed to Section 4-16 for 4T Mo-
mentary, [SEL] [H4E], operation. Se-
quencer option required to reconfigure
for 4T Momentary.
Proceed to Section 4-17 for Spot Con-
trol, [SEL] [SPO], Operation.
NOTE: After 2T has been reconfigured
and one of the reconfigured functions is
selected during normal operation, upon
power up, H-4, H4L, H4E, or SPO will be dis-
played for 5 seconds as a reminder to
the operator.
2
4
H-2
SEL
Non CE Models Only
Rear Panel